Relay

The T154T119 and RIS2 temperature and protection relays for winding monitoring are electronic devices that monitor and control the temperature of dry type and cast resin transformers and oil-filled transformers.

En savoir plus
Filter By
€772.00 (tax excl.)
The RIS2 protection relay is a safety detector for distribution transformers. It's an essential accessory in the protection of your oil transformer. It allows continuous control of the pressure, temperature, oil level...
Showing 1-4 of 4 item(s)

As part of a modern approach to transformer thermal management, these units combine precise measurement, alarm functions, and auxiliary controls to protect windings and insulation systems. When properly configured, a temperature relay and a protection relay become the core of the monitoring system, ensuring reliable and long-term operation.

Essential Functions for Winding Protection

Accurate Measurement and Suitable Sensors

Control begins with reliable measurement. Depending on the system architecture, a winding temperature sensor using RTD technology (such as PT100 transformer sensors) or NTC sensors provides thermal rise measurements as close as possible to the copper windings. Top-oil and hot-spot data can be complemented through a thermal indicator for transformers or a thermal monitoring relay. This combination delivers a realistic view of load behavior and allows anticipation of deviations related to ventilation, environmental conditions, or equipment aging.

Alarm Thresholds and Progressive Tripping Functions

Thresholds are generally staged as follows: pre-alarm, alarm, and then trip. A temperature alarm relay provides an alert as soon as values start deviating from nominal operating conditions; the thermal control device can then activate fans, start a pump, or trigger upstream switchgear. Hysteresis, holding time, and delay settings prevent oscillations, improve transformer thermal safety, and extend insulation lifespan.

Integration with Dry-Type and Oil-Immersed Transformers

Cast Resin Dry-Type Transformers

For cast resin transformers, winding monitoring is the top priority. A transformer thermostat or transformer thermal relay controls two-speed forced ventilation and manages alarm contact activation. In this context, the winding protection relay supports multiple RTD inputs, calculates the maximum value, applies threshold settings, and records events. The objective is to maintain stable transformer temperature control despite load fluctuations and ventilation grid dust accumulation.

Oil-Immersed Distribution Transformers

For oil-filled transformers, priority is given to hot-spot and top-oil monitoring. An oil temperature relay contributes to thermal monitoring of oil-filled transformers in addition to the dial thermometer. Fan or oil circulation control is managed through a thermal control module coordinating different cooling stages. The system differentiates between gradual heating and sudden temperature increases in order to preserve the integrity of seals, bushings, and electrical connections.

Selection, Configuration, and Communication

Relevant Selection Criteria

When selecting a transformer temperature relay, key considerations include the number of sensor inputs, compatibility (Pt100, Pt1000, NTC), available alarm levels, and relay output power ratings. Self-test functions, event logs, accuracy class, and compliance with standards (for example IEC 60076-7 for thermal models) also influence the decision. A digital temperature relay provides trend curves, hot-spot calculations, and configurable cooling scenarios.

Local and Remote Monitoring

Connectivity simplifies maintenance operations. Through Modbus, RS-485, or Ethernet protocols, transformer thermal instrumentation transmits operating values to monitoring systems. Maintenance teams can review historical data, adjust threshold settings, and document incidents. Depending on the application, an additional transformer monitoring accessory (audible alarm, visual indicator, data recorder) can improve visibility within substations. Data then becomes a valuable tool for predictive load management and informed decision-making between performance optimization and equipment longevity.

Installation, Testing, and Maintenance

Careful Commissioning

A reliable installation begins with shielded sensor cables, routing paths separated from power conductors, and proper grounding. Input identification, verification of installation orientation, and temperature simulation tests (resistance bridges, thermal baths) validate the measurement chain. Threshold settings should account for site-specific conditions such as altitude, ambient temperature, load cycles, available ventilation, and operator requirements.

Operation and Diagnostics

Once in operation, periodic testing ensures system availability. Trend analysis makes it possible to detect deviations such as a seized fan, disconnected sensor, or insufficient oil circulation long before a major failure occurs. Combining an appropriate thermal control device with a condition-based maintenance plan minimizes unplanned downtime, optimizes energy dissipation, and strengthens thermal protection for transformers. For wiring diagrams, configuration assistance, or product selection guidance, feel free to contact us. A direct discussion often allows your system configuration to be refined quickly and efficiently.