• Payment by bank transfer and credit card Payment by bank transfer and credit card
  • Delivery policy (edit with the Customer Reassurance module) Delivery policy (edit with the Customer Reassurance module)

Insulating plate

TECHNIKELEC® offers PTFE insulating plates to insulate electrical transformers from noise generated by vibrations. They are intended for industrial use and have many features for your transformers.

The insulating plates are placed under the transformers and can be used for power transformers or between two equipments genererating vibrations.

En savoir plus
  • Teflon plate

    Teflon plate

    Teflon has very interesting insulating properties for the electrical industry. You will find in this section insulating plates of different sizes and thicknesses ensuring a very good electrical insulation between 2 equipments placed one on top of the other. In particular, for the insulation of the tank mass of transformers.

Filter By
À partir de €362.00
Set of 4 teflon insulating plates (PTFE) to electrically isolate the transformer from its support and to promote the isolation of the tank. They are placed between the down supports of the electrical transformer...
Showing 1-2 of 2 item(s)

Insulating Plate for Electrical Transformer

The safety of your electrical installations depends on properly selected equipment. Positioned directly beneath your machines, the transformer insulating plate plays a key role. It secures the high-voltage area, ensures the stability of the equipment on the ground, and effectively blocks leakage currents. It is an essential component for reducing mechanical stress within your working environment.

What Is an Electrical Insulating Plate Used For?

Insulating the Transformer from Its Support Structure

An electrical transformer generates power, but it also creates significant physical stresses. Installing it directly on the floor or on metal rails is risky, as it increases the likelihood of electrical incidents. Adding an electrical insulating plate creates a true physical barrier. By clearly separating the machine from the transformer support structure, you prevent current leakage into nearby infrastructure, thereby protecting your building’s foundations.

Enhancing Tank-to-Ground Insulation

Protecting your personnel and electrical network leaves no room for compromise. The purpose of tank-to-ground insulation is straightforward: preventing an internal fault from reaching the machine’s metal enclosure. This is where a properly designed insulating surface plays a crucial role. It eliminates any possible electrical path between the equipment and the ground. As a result, your equipment is far less vulnerable to overvoltages, and neutral grounding systems become easier to manage.

PTFE Insulating Plate: A Solution Tailored for Transformers

The Insulating Properties of Teflon

Dans certains milieux, on ne peut pas utiliser n'importe quel matériau. La plaque isolante PTFE sort du lot grâce à son inertie chimique et sa tenue aux températures extrêmes. Plus connue sous le nom de plaque en téflon, rien ne l'abîme, ni les huiles diélectriques, ni les intempéries. Elle offre donc une isolation électrique pour le transformateur ultra fiable, tout en gardant ses propriétés mécaniques intactes même quand la charge varie ou que le mercure grimpe d'un coup.

Une utilisation sous le transformateur ou entre deux équipements

Cette solution est très flexible, un vrai plus pour les industriels. Si on la glisse généralement sous le transformateur pour l'isoler du sol, elle sert aussi à autre chose. Quand l'espace manque, elle est parfaite pour garantir une isolation entre divers équipements collés les uns aux autres. Cette séparation bloque les arcs électriques qui voudraient passer d'une machine à l'autre. Chaque circuit reste bien isolé dans son coin, ce qui évite les mauvaises réactions en chaîne en cas de panne.

Reducing Vibrations and Noise Pollution

Insulating Plates and Anti-Vibration Plates

As is well known, alternating current generates a constant humming noise. This transformer noise pollution can quickly become disruptive, especially in urban areas or enclosed facilities. Fortunately, some support solutions serve a dual purpose. An anti-vibration plate for transformers does more than block electrical current—it also absorbs noise and vibrations. With a single component, you can address both electrical and acoustic concerns. Your teams will appreciate the quieter working environment.

Dampening Vibrations from Electrical Equipment

During operation, the machine generates vibrations, and these micro-movements can quickly wear out fasteners and cables. These transformer vibrations can even propagate through concrete structures and steel frameworks. Installing a resilient support beneath the equipment provides effective vibration reduction. Components experience significantly less wear, and by absorbing the constant shocks transmitted through the frame, you can greatly extend the service life of the entire installation.

Choosing the Right Industrial Insulating Plate

According to the Type of Transformer

Every machine has its own requirements. Naturally, a small distribution substation does not require the same setup as a large power transformer. Weight is the primary factor in determining the required density of the plate. If several tons are placed on a support that is too soft, it will compress and lose its effectiveness. Be sure to verify the maximum load capacity of the insulating plate before making your selection.

Based on Thickness, Material, and Intended Application

When it comes to industrial electrical insulation, precision is essential. The thickness of the plate directly determines its dielectric strength and resistance to electrical breakdown. A thin elastomer layer may be sufficient for a modest installation, but high-voltage applications require more robust solutions. At TECHNIKELEC, we make the process easier with readily available stock products that are ready for shipment. All that remains is to select the material that best suits your actual operating conditions, whether that involves exposure to hydrocarbons, extreme temperatures, or the need for enhanced noise reduction.

A Safer Setup for Your Infrastructure

Completing an electrical installation requires close attention to every detail. This simple protective component placed beneath the machine can make the difference between a reliable system and a high-risk installation. It stabilizes your equipment, prevents stray currents, and protects your investment for years to come. Choosing the right solution helps avoid costly future failures and complications during inspections. Unsure about the ideal dimensions or material for your project? The TECHNIKELEC team is here to help. We work with you to understand your constraints and identify the most suitable product reference, simply and directly.